Crowcon T3 Gas Detector
Enquire about this product
Hire This Product
Product Servicing
Enquire about this course
Send us your questions about this product and we will endeavour to get back to you as soon as possible!
If you’re look to hire one of our products, simply fill out this form with your full requirements and we’ll get back to you regarding a quotation.
Take advantage of our on-site repair and calibration service; simply fill out this form and we will get back to you as soon as possible!
Crowcon T3 Gas Detector
Call for Price
£0.00 inc VAT
Enquire about this product
Hire This Product
Product Servicing
Enquire about this course
Send us your questions about this product and we will endeavour to get back to you as soon as possible!
If you’re look to hire one of our products, simply fill out this form with your full requirements and we’ll get back to you regarding a quotation.
Take advantage of our on-site repair and calibration service; simply fill out this form and we will get back to you as soon as possible!
Crowcon T3 Gas Detector
Call for Price
£0.00 inc VAT
Crowcon T3 Gas Detector
The Crowcon T3 is an intuitive multi-sensor gas detector used to guard against a wide range of toxic and flammable gases.
Featuring a top-mounted display for ease of use and quick decision-making. This detector includes a one-button operation and an optional external filter to help reduce maintenance time.
The T3 delivers top performance in a robust, lightweight package. The added dust and water resistance this gas detector provides caters well to demanding operations where the working environment can be extreme.
Powered by a long-lasting rechargeable lithium-ion battery the Crowcon T3 can provide up to 14 hours of operation.
Click here to find out what other Crowcon gas detector spares & accessories we have to offer; also check out our handy blog article on The Origin of Portable Gas Detectors.
Specifications
Size | 114 x 71 x 48mm (tapers to 20mm) (4.5 x 2.8 x 1.9ins) |
Weight | 295g (10.4oz) |
Alarms | 95dB multiple alarm sounds allow selection of distinctive tones for different alarm levels Internal vibrating alarm |
Display | Graphic LCD with backlight, giving simultaneous display for all gas channels. Graphic symbols for battery (with proportional indication of remaining operation time), healthy operation or fault warning. Start up indication when calibration is due, overdue, or service required. Normal display: Real time gas concentration levels Display recall: Peak readings and TWA |
Data logging | Timed: 50 hours at 1-minute data rate (>12,000 data logs of 4 channels) Threshold: Starts after adjustable pre-set level Event: >5,000 events |
Event logging | Alarm, over range, calibration, bump, on/off, TWA, 1000 events |
Battery | Rechargeable Li-ion battery |
Operating time | Based on four-gas instrument fitted with flammable sensor: A 5-hour charge from flat provides at least 12 hours of continuous use.A 12-hour charge provides at least 14 hours of continuous use |
Sampling | Diffusion or hand aspirator |
Operating temperature | -20°C to +55°C (-4°F to +131°F) |
Storage | -25°C to +65°C (-13°F to +149°F) |
Humidity | 20 to 90% RH@ 40°C non-condensing |
Ingress protection | IP65 and IP67 |
Approvals | ATEX II 2 G Ex ia d IIC T4 Gb (-20°C ≤ Ta ≤ +55°C) BASEEFA05ATEX0187 IECEx Ex ia d IIC T4 Gb (-20°C ≤ Ta ≤ +55°C) BAS05.0059 CSA Class I Division 1 Groups A, B, C and D |
Safety standards | EN60079-0, EN60079-11, EN60079-1 CSA22.2, 152 EN50270, EN50271, EN50104, EN45544, EN60079, IEC61508 |
PC Interface | RS232 connection from interface module in charger RS232/USB converter available |
Calibration | Can be routinely calibrated using Portables PC software or Crowcon Checkbox IMH |
Charging | Single way drop-in charger with UK, EU or US plug or in-line 110V/220V supply Single way drop-in charger with options as above including PC interface 5 way multi-charger with universal power supply Vehicle adapter for in-vehicle charging Universal charger for vehicle, wall and desk mounting with a multi-region plug (supplied with EU/UK/US/Australian inserts) and status indication |
Sensor Ranges
Gas | Range | Typical Alarm (UK) |
*Flammable | 0- 100% LEL | 20% |
Oxygen (O2) | 0-25% | 19/23.5% |
Hydrogen sulphide (H2S) | 0-100ppm | 5ppm |
Carbon monoxide (CO) | 0-500ppm | 30ppm |
Sulphur dioxide (SO2) | 0-20ppm | 1ppm |
Ozone (O3) | 0-1ppm | 0.1ppm |
Ammonia (NH3) | 0-100ppm | 25ppm |
**Carbon dioxide (CO2) | 0-5% | 0.5% |
Carbon monoxide (CO) H₂ compensated | 0-500ppm | 30ppm |
Hydrogen Cyanide (HCN) | 0-30ppm | 10ppm |
We are committed to offering the best products, at the very best rates on the market. If you can find a better offer, we will endeavour to not only match, but beat it!
To Find out more about our policy and to see how you would qualify for our price promise, click here.