Control Panels
Control Panels receive signals from fixed sensor heads placed around a facility, analysing gas concentrations to ensure that employees stay safe from dangerous levels of gas. When a sensor detects a hazardous gas level, the control panel can trigger alarms and activate ventilation systems. This integration of detection and control makes gas detection systems far more effective than standalone sensors alone.
At Rockall Safety, we supply and support control panels from leading manufacturers including Crowcon, Honeywell, Teledyne, and MSA. Our long standing partnerships with these industry leaders allow us to provide customers with the latest technology.
Control panels are designed to manage multiple sensor inputs. They provide real time readings, visual and audible alerts. Many control panels can also interface with existing building management systems, allowing automated processes such as ventilation and alarms.
Control panel are used in industries like chemical manufacturing, oil and gas, wastewater treatment, pharmaceuticals, and construction.
For more information, call 02920 759 683 or complete the form here.
Control Panels
Control Panels receive signals from fixed sensor heads placed around a facility, analysing gas concentrations to ensure that employees stay safe from dangerous levels of gas. When a sensor detects a hazardous gas level, the control panel can trigger alarms and activate ventilation systems. This integration of detection and control makes gas detection systems far more effective than standalone sensors alone.
At Rockall Safety, we supply and support control panels from leading manufacturers including Crowcon, Honeywell, Teledyne, and MSA. Our long standing partnerships with these industry leaders allow us to provide customers with the latest technology.
Control panels are designed to manage multiple sensor inputs. They provide real time readings, visual and audible alerts. Many control panels can also interface with existing building management systems, allowing automated processes such as ventilation and alarms.
Control panel are used in industries like chemical manufacturing, oil and gas, wastewater treatment, pharmaceuticals, and construction.
For more information, call 02920 759 683 or complete the form here.
- BEST SELLER
SKU: MX16
Teledyne MX16 Control Panel
- Gas Detection Class Fixed
- ATEX Non ATEX
- Display LCD back-lit display + smart keys
- Temperature -20°C to +50°C (-4°F to +122°F)
- Brand Teledyne
- Part Numbers MX16-A-239-1-0-0 MX16 controller, one analog (4-20mA) input for CO2 (0-5%) Vol) with RS485, MX16-0-000-1-0-0 MX16 Controller, one analog (4-20mA) or digital input, MX16-A-001-0-0-0 MX16 controller, one analog (4-20mA) input for CH4 (0-100% LEL), MX16-A-001-1-0-0 MX16 controller, one analog (4-20mA) input for CH4 (0-100% LEL), with RS485, MX16-A-003-0-0-0 MX16 controller, one analog (4-20mA) input for H2 (0-100% LEL), MX16-A-003-1-0-0 MX16 controller, one analog (4-20mA) input for H2 (0-100% LEL), with RS485, MX16-A-032-0-0-0 MX16 controller, one analog (4-20mA) input for LPG (0-100% LEL), MX16-A-032-1-0-0 MX16 controller, one analog (4-20mA) input for LPG (0-100% LEL) with RS485, MX16-A-200-0-0-0 MX16 controller, one analog (4-20mA) input for O2 (0-30%) Vol), MX16-A-200-1-0-0 MX16 controller, one analog (4-20mA) input for O2 (0-30%) Vol) with RS485, MX16-A-239-0-0-0 MX16 controller, one analog (4-20mA) input for CO2 (0-5%) Vol), MX16-0-000-0-0-0 MX16 Controller, one analog (4-20mA) or digital input
View product - BEST SELLER
SKU: MX32-3
Teledyne MX32 Control Panel
- Gas Detection Class Fixed
- ATEX Non ATEX
- Temperature -20°C to +50°C (-4°F to +122°F)
- Display LCD back-lit display + smart keys
- Brand Teledyne
View product - BEST SELLER
SKU: WMX43
Teledyne MX 43 SIL1 Certified Gas Detection Controller
- Gas Detection Class Fixed
- ATEX Non ATEX
- Display LCD back-lit display + smart keys
- Channels 8 Channels
- Power Consumption 100-240 Vac 50-60 Hz or 21-28 vdc, 112 W max
- Brand Teledyne
View product - BEST SELLER
SKU: GMS-BDL-1
Crowcon Gasmaster Control Panel
- Gas Detection Class Fixed
- ATEX Non ATEX
- Display LCD display
- Channels 4 channels
- Power Consumption 100-240Vac 50-60Hz or 20-30Vdc, 60W max
- Brand Crowcon
- Part Numbers 4 Channel, 1 mA & 1 mV modules, CE Label, Communication Port, 4 Channel, 0 mA & 3 mV modules, CE Label, Communication Port, 1 Channel, 2 mA & 2 mV modules, CE Label, Communication Port, 4 Channel, 1 mA & 2 mV modules, CE Label, Communication Port, 4 Channel, 0 mA & 4 mV modules, CE Label, Communication Port, 1 Channel, 3 mA & 0 mV modules, CE Label, Communication Port, 4 Channel, 1 mA & 3 mV modules, CE Label, Communication Port, 1 Channel, 3 mA & 1 mV modules, CE Label, Communication Port, 4 Channel, 2 mA & 0 mV modules, CE Label, Communication Port, 1 Channel, 4 mA & 0 mV modules, CE Label, Communication Port, 4 Channel, 2 mA & 1 mV modules, CE Label, Communication Port, 1 Channel, 0 mA & 0 mV modules, CE Label, Communications Port, 1 Channel, 0 mA & 1 mV modules, CE Label, Communication Port, 4 Channel, 2 mA & 2 mV modules, CE Label, Communication Port, 1 Channel, 1 mA & 0 mV modules, CE Label, Communications Port, 1 Channel, 0 mA & 2 mV modules, CE Label, Communication Port, 4 Channel, 3 mA & 0 mV modules, CE Label, Communication Port, 1 Channel, 1 mA & 1 mV modules, CE Label, Communications Port, 1 Channel, 0 mA & 3 mV modules, CE Label, Communication Port, 4 Channel, 3 mA & 1 mV modules, CE Label, Communication Port, 1 Channel, 1 mA & 2 mV modules, CE Label, Communications Port, 1 Channel, 0 mA & 4 mV modules, CE Label, Communication Port, 4 Channel, 4 mA & 0 mV modules, CE Label, Communication Port, 1 Channel, 1 mA & 3 mV modules, CE Label, Communications Port, 4 Channel, 0 mA & 0 mV modules, CE Label, Communication Port, 4 Channel, 0 mA & 1 mV modules, CE Label, Communication Port, 1 Channel, 2 mA & 0 mV modules, CE Label, Communication Port, 4 Channel, 1 mA & 0 mV modules, CE Label, Communication Port, 4 Channel, 0 mA & 2 mV modules, CE Label, Communication Port, 1 Channel, 2 mA & 1 mV modules, CE Label, Communication Port
View product SKU: TPPLWXAXXSNXXX
Honeywell Touchpoint Plus Control Panel
- Gas Detection Class Fixed
- ATEX Non ATEX
- Power Consumption Max. 105 W (including detector and external devices), max. 210 W with expansion unit
- Display 7’’ color LCD touchscreen. Graphic User Interface
- Temperature -10 °C to +55 °C
- Brand Honeywell
- Part Numbers 8 channels with AC supply and wall mounted enclosure. Supplied complete with 2x mV inputs, including 1, 2 and Master Fault., 8 channels with AC supply and wall mounted enclosure. Supplied complete with 4x mA inputs, including 1, 2 and Master Fault., 8 channels with AC supply and wall mounted enclosure. Supplied complete with 4x mV inputs, including 1, 2 and Master Fault., 8 channels with AC supply and wall mounted enclosure. Supplied complete with 2x mA and 2x mV inputs, including 1, 2 and Master Fault., 8 channels with AC supply and wall mounted enclosure. Supplied complete with 8x mA inputs, including 1, 2 and Master Fault., 8 channels with AC supply and wall mounted enclosure. Supplied complete with 8x mV inputs, including 1, 2 and Master Fault., 8 channels with AC supply and wall mounted enclosure. Supplied complete with 4x mA and 4x mV inputs, including 1, 2 and Master Fault., 8 channels with AC supply and wall mounted enclosure. Supplied complete with 8x mA inputs, 24 programmable relays, and with battery backup., 8 channels with AC supply and wall mounted enclosure. Supplied complete with 8x mV inputs, 24 programmable relays, and with battery backup., 8 channels with AC supply and wall mounted enclosure. Supplied complete with 2x mA inputs, including 1, 2 and Master Fault.
View productSKU: TPPLWXAXXSNXXX-1
Honeywell Touchpoint™ Plus Wireless Controller
- Gas Detection Class Fixed
- ATEX Non ATEX
- Power Consumption Max. 105 W (including detector and external devices), max. 210 W with expansion unit
- Display 7’’ color LCD touchscreen. Graphic User Interface
- Temperature -10 °C to +55 °C
- Brand Honeywell
- Part Numbers 64 wireless channels, 2.4GHz, with DC supply and wall mounted enclosure. Supplied complete with 12x relays., 64 wireless channels, 2.4GHz, with DC supply and wall mounted enclosure. Supplied complete with 8x mA input, 12x relays, battery , Modbus, TCP., 64 wireless channels, 2.4GHz, with AC supply and wall mounted enclosure. Supplied complete with 12x relays, battery backup and Modbus RTU and TCP., 64 wireless channels, 2.4GHz, with AC supply and wall mounted enclosure. Supplied complete with 8x mA input, 12x relays, battery backup and Modbus RTU and TCP.
View productSKU: 2306BX000
Honeywell Unipoint Control Panel
- Gas Detection Class Fixed
- ATEX ATEX
- Display backlit display
- Temperature -10 to + 45 °C
- Gas Type Flammable Toxic
- Brand Honeywell
- Part Numbers 2306B2000 Unipoint controller (mV input version), 2306B1000 Unipoint controller (mA input version)
View productSKU: VortexFP4
Crowcon Vortex Fixed Gas Control Panel
- Gas Detection Class Fixed
- ATEX Non ATEX
- Display 441 x 128mm (cut-out 366 x 84.5mm)
- Channels 12 channels
- Power Consumption 110Vac or 240Vac 3.2A max 150W PSU 20 - 30Vdc
- Brand Crowcon
- Part Numbers Vortex with 12x Input Channels & 2x Relay Modules, Vortex with 4x Input Channels & 3x Relay Modules, Vortex with 8x Input Channels & 3x Relay Modules, Vortex with 4x Input Channels & No Relay Modules, Vortex with 12x Input Channels & 3x Relay Modules, Vortex with 8x Input Channels & No Relay Modules, Vortex with 4x Input Channels & 4x Relay Modules, Vortex with 12x Input Channels & No Relay Modules, Vortex with 8x Input Channels & 4x Relay Modules, Vortex with 4x Input Channels & 1x Relay Modules, Vortex with 8x Input Channels & 1x Relay Modules, Vortex with 12x Input Channels & 1x Relay Modules, Vortex with 4x Input Channels & 2x Relay Modules, Vortex with 8x Input Channels & 2x Relay Modules
View productSKU: DRA-REGARD-3000
Dräger REGARD® 3000 Control Panel
- Gas Detection Class Fixed
- ATEX Non ATEX
- Temperature -20 ... +55 °C
- Brand Dräger
View productSKU: DRA-REGARD-3900
Dräger REGARD® 3900 Control Panel
- Gas Detection Class Fixed
- ATEX Non ATEX
- Brand Dräger
View productSKU: 10204450
MSA Chillgard 5000 Control Panel
- Gas Detection Class Fixed
- ATEX Non ATEX
- Power Consumption 100–240 Vac, 50/60 Hz, 200 VA maximum Supply voltage not to fluctuate more than ±10%
- Temperature 32–122°F (0 to 50°C)
- Output 4–20 mA sourcing, 250 Ohm load; 0–10 V, 2 K Ohm minimum load; RS485 Modbus RTU; RS-485 BACnet MS/TP
- Brand MSA
View productSKU: MSA-CHILLGARD5-RF
MSA Chillgard 5000 Refrigerant Control Panel
- Gas Detection Class Fixed
- ATEX Non ATEX
- Temperature 32°F to 122°F (0°C to 50°C)
- Output None
- Gas Type Refrigerants
- Brand MSA
View productSKU: 9602-0XXX20
Honeywell Satellite XT Control Panel
- Gas Detection Class Fixed
- ATEX Non ATEX
- Temperature -20°C up to +40°C
- Display Graphic Display 122 x 32 dots with backlight
- Power Consumption Satellite XT FTT max. 0.6w
- Gas Type Chlorine - Cl2, Methyl Fluoride, Sulfur Dioxide - SO2, Chlorine Dioxide - ClO2, Nitrogen Trifluoride, Hydrogen - H, Sulphur Hexafluoride, Hydrogen Chloride - HCl, Phosgene - COCl2, Arsine - AsH3, Hydrogen Fluoride - HF, Diborane - B2H6, Hydrogen Sulfide - H2S, Bromine -Br2, Methane - CH4, Hexamethyldisilazane, Nitrogen Dioxide - NO2, Hydrazine, Nitric Oxide - NO, Hexafluoro-1,3-butadiene, Oxygen - O2, Ammonia - NH3, Octafluorocyclopentene, Ozone - O3
- Brand Honeywell
- Part Numbers 9602-0406 Satellite XT FTT/R with ½” RA Connector., 9602-0450 Satellite Digital FTT LEL DIN RAIL W., 9602-0451 Satellite XT FTT/C with ½” RA Connector., 9602-0505 MST Satellite XT R., 9602-0200 Satellite Analog 4-20mA GENERIC DIN R., 9612-0200 Satellite Analog 4-20mA NEMA 4X., 9602-0201 Satellite XT 4-20mA with ½” RA Connector., 9612-0205 Satellite XT 4-20mA WITH RELAYS IP 65., 9602-0205 Satellite Analog 4-20mA W/RELAYS DIN., 9612-0250 MST Satellite XT 4-20mA/C., 9602-0206 Satellite XT 4-20mA/R with ½” RA Connector., 9612-0255 MST Satellite XT 4-20mA/C/R., 9602-0251 Satellite XT 4-20mA/C with ½” RA Connector., 9612-0400 Satellite Digital FTT NEMA 4X W/BACKLIG., 9602-0255 MST Satellite XT 4-20mA/C/R., 9612-0405 MST Satellite FTT/R., 9602-0405 Satellite Digital FTT W/RELAYS DIN RA.
View product
FAQs
A gas detection control panel is the central system that monitors signals from connected gas detectors and sensors.
Control panels continuously receive signals from multiple gas detectors installed across a facility. When a detector senses a gas above the set threshold, the panel processes the signal and triggers alarms.
Control panels can monitor a wide range of gases depending on the detectors they are connected to. This can include flammable gases like methane, toxic gases such as hydrogen sulphide and carbon monoxide, and oxygen levels.