Products
At Rockall Safety, our core principle is to provide customers with the highest quality professional safety equipment, featuring the latest technological innovations. We understand the importance of reliable safety tools, and our mission is to ensure you and your workforce are protected in all environments. Whether you’re working in an office or a hazardous location where toxic chemicals are present, we offer the equipment you need to maintain the highest safety standards.
We proudly partner with top-tier safety brands across the UK and Europe, including Dräger, Honeywell, Ridgegear, and Globestock. By collaborating with these trusted names, we’re able to supply state-of-the-art gas detectors, fall arrest equipment, and breathing apparatus that meet the stringent demands of a wide range of industries. Our product offerings are designed to support you when it matters most, providing reliable performance in critical situations.
Products
At Rockall Safety, our core principle is to provide customers with the highest quality professional safety equipment, featuring the latest technological innovations. We understand the importance of reliable safety tools, and our mission is to ensure you and your workforce are protected in all environments. Whether you’re working in an office or a hazardous location where toxic chemicals are present, we offer the equipment you need to maintain the highest safety standards.
We proudly partner with top-tier safety brands across the UK and Europe, including Dräger, Honeywell, Ridgegear, and Globestock. By collaborating with these trusted names, we’re able to supply state-of-the-art gas detectors, fall arrest equipment, and breathing apparatus that meet the stringent demands of a wide range of industries. Our product offerings are designed to support you when it matters most, providing reliable performance in critical situations.
-
Gas Detection
-
Fall Protection
-
Respiratory Protection
-
Body Protection
-
Lighting
-
Communication Equipment
-
Cable Location & Thermal Cameras
-
Drug & Alcohol Testers
SKU: DF-TV7
Teledyne DF-TV7 IR3 Fixed Flame Detector
- Gas Detection Class Fixed
- ATEX ATEX
- Power Consumption 2W normal; 4W during test
- Brand Teledyne
View productSKU: DF-TV7-V/IR2
Teledyne MultiFlame DF-TV7-V/IR2 Flame Detector
- Gas Detection Class Fixed
- ATEX ATEX
- Power Consumption 2W normal, 4w during test
- Brand Teledyne
View productSKU: SG50-F - UV/IR (V)
Teledyne Spyglass SG50 – UV/IR Optical Flame Detector
- Gas Detection Class Fixed
- ATEX ATEX
- Brand Teledyne
View productSKU: SG50-F-IR3-H2-V
Teledyne Spyglass™ IR3 – H2 Flame Detector
- Gas Detection Class Fixed
- ATEX ATEX
- Brand Teledyne
View productSKU: SG50-F-IR3-V
Teledyne Spyglass™ IR3 – Optical Flame Detector
- Gas Detection Class Fixed
- ATEX ATEX
- Brand Teledyne
View productSKU: SG50-F-UVIR-AS10
Spyglass™ Xtend Triple-Infrared Flame Detector
- Gas Detection Class Fixed
- ATEX ATEX
- Temperature -50°C - 85°C
- Brand Teledyne
View productSKU: 700-GAS
Teledyne 700 Series Fixed Gas Detector
- Gas Detection Class Fixed
- ATEX ATEX
- Output Linear 4-20 mA DC RS-485 MODBUS-RTU
- Power Consumption 11 - 30 VDC
- Cable Entry 3-wire shielded cable
- Brand Teledyne
View productSKU: CTX300
Teledyne CTX 300 Fixed Gas Detector
- Gas Detection Class Fixed
- ATEX ATEX
- Display Highly visible backlight display
- Temperature -40 to +50 degrees
- Cable Entry PG9 cable gland
- Power Consumption CTX 300 with display unit - 110 mA
- Gas Type Carbon Dioxide - CO2, Toxic gases, Oxygen - O2, Combustible Gases
- Brand Teledyne
- Part Numbers WC3AHLA - The CTX 300 fixed gas detector With Display Version - Electrochemical Version - HCl, Hydrogen chloride 0-30 ppm, WC3ASOA - The CTX 300 fixed gas detector With Display Version - Electrochemical Version - SO2, Sulfur dioxide 0-10 ppm, WC3A-243 - The CTX 300 fixed gas detector With Display Version - Electrochemical Version - ASH3, Arsine - 0-1 ppm, WC3AHNB - The CTX 300 fixed gas detector With Display Version - Electrochemical Version - HCN, Hydrogen cyanide 0-30 ppm, WC3ASOC - The CTX 300 fixed gas detector With Display Version - Electrochemical Version - SO2, Sulfur dioxide 0-100 ppm, WC3ACL2 - The CTX 300 fixed gas detector With Display Version - Electrochemical Version - Cl2, Chlorine - 0-10 ppm, WC3AHFA - The CTX 300 fixed gas detector With Display Version - Electrochemical Version - HF, Hydrogen fluoride 0-10 ppm, WC3ACLO - The CTX 300 fixed gas detector With Display Version - Electrochemical Version - Cl2, Chlorine Dioxide - 0-3 ppm, WC3A-262 - The CTX 300 fixed gas detector With Display Version - Electrochemical Version - HNO3, Acide Nitrique 0-10 ppm, WC3ACOA - The CTX 300 fixed gas detector With Display Version - Electrochemical Version - CO, Carbon Monoxide - 0-100 ppm, WC3ANH3 - The CTX 300 fixed gas detector With Display Version - Electrochemical Version - NH3, Ammonia 0-100 ppm, WC3ACCL - The CTX 300 fixed gas detector With Display Version - Electrochemical Version - COCl2, Phosgene - 0-3 ppm, WC3ANOA - The CTX 300 fixed gas detector With Display Version - Electrochemical Version - NO, Nitric oxide 0-100 ppm, WC3AOET - The CTX 300 fixed gas detector With Display Version - Electrochemical Version - C2H40, Ethylene Oxyde - 0-30 ppm, WC3AN2A - The CTX 300 fixed gas detector With Display Version - Electrochemical Version - NO2, Nitrogen dioxide 0-10 ppm, WC3AF2A - The CTX 300 fixed gas detector With Display Version - Electrochemical Version - F2, Fluorine 0-1 ppm, WC3AO2F - The CTX 300 fixed gas detector With Display Version - Electrochemical Version - O2, Oxygen 0-30 % Vol. 2 year sensor lifetime, -20°C, WC3AH2S - The CTX 300 fixed gas detector With Display Version - Electrochemical Version - H2, Hydrogen 0-2000 ppm, B301072 - The CTX 300 fixed gas detector With Display Version - Electrochemical Version - O2 Oxygen 0-30 % Vol. Special for Helium enrichment, WC3AHSA - The CTX 300 fixed gas detector With Display Version - Electrochemical Version - H2S, Hydrogen sulfide 0-30 ppm, WC3AO3A - The CTX 300 fixed gas detector With Display Version - Electrochemical Version - O3, Ozone 0-1 ppm, WC3AHSC - The CTX 300 fixed gas detector With Display Version - Electrochemical Version - H2S, Hydrogen sulfide 0-1000 ppm, WC3APH3 - The CTX 300 fixed gas detector With Display Version - Electrochemical Version - PH3, Phosphine 0-1 ppm
View productSKU: GD10-P00-23AN-0XH-00
Teledyne GD10 Series – Infrared Gas Detector
- Gas Detection Class Fixed
- ATEX ATEX
- Output 4 to 20 mA, HART
- Power Consumption 24 VDC
- Cable Entry M20 Ex e cable gland
- Brand Teledyne
View productSKU: MS-GAS
Teledyne MicroSafe Series Fixed Gas Detector
- Gas Detection Class Fixed
- ATEX ATEX
- Output 4 to 20 mA, HART
- Power Consumption 12-28 VDC
- Gas Type Flammable - LEL
- Brand Teledyne
View product- BEST SELLER
SKU: WMX43
Teledyne MX 43 SIL1 Certified Gas Detection Controller
- Gas Detection Class Fixed
- ATEX Non ATEX
- Display LCD back-lit display + smart keys
- Channels 8 Channels
- Power Consumption 100-240 Vac 50-60 Hz or 21-28 vdc, 112 W max
- Brand Teledyne
View product - BEST SELLER
SKU: MX16
Teledyne MX16 Control Panel
- Gas Detection Class Fixed
- ATEX Non ATEX
- Display LCD back-lit display + smart keys
- Temperature -20°C to +50°C (-4°F to +122°F)
- Brand Teledyne
- Part Numbers MX16-0-000-0-0-0 MX16 Controller, one analog (4-20mA) or digital input, MX16-A-239-1-0-0 MX16 controller, one analog (4-20mA) input for CO2 (0-5%) Vol) with RS485, MX16-0-000-1-0-0 MX16 Controller, one analog (4-20mA) or digital input, MX16-A-001-0-0-0 MX16 controller, one analog (4-20mA) input for CH4 (0-100% LEL), MX16-A-001-1-0-0 MX16 controller, one analog (4-20mA) input for CH4 (0-100% LEL), with RS485, MX16-A-003-0-0-0 MX16 controller, one analog (4-20mA) input for H2 (0-100% LEL), MX16-A-003-1-0-0 MX16 controller, one analog (4-20mA) input for H2 (0-100% LEL), with RS485, MX16-A-032-0-0-0 MX16 controller, one analog (4-20mA) input for LPG (0-100% LEL), MX16-A-032-1-0-0 MX16 controller, one analog (4-20mA) input for LPG (0-100% LEL) with RS485, MX16-A-200-0-0-0 MX16 controller, one analog (4-20mA) input for O2 (0-30%) Vol), MX16-A-200-1-0-0 MX16 controller, one analog (4-20mA) input for O2 (0-30%) Vol) with RS485, MX16-A-239-0-0-0 MX16 controller, one analog (4-20mA) input for CO2 (0-5%) Vol)
View product - BEST SELLER
SKU: MX32-3
Teledyne MX32 Control Panel
- Gas Detection Class Fixed
- ATEX Non ATEX
- Temperature -20°C to +50°C (-4°F to +122°F)
- Display LCD back-lit display + smart keys
- Brand Teledyne
View product - BEST SELLER
SKU: 6513559
Teledyne OLCT 10 and OLC 10 Fixed Gas Detectors
- Gas Detection Class Multi Gas, Fixed
- ATEX ATEX
- Temperature -10 to + 45 °C
- Output Normal operation 4-20 mA (Fault 23.2 mA)
- Gas Type Combustible Gases, Butane - C4H10, Natural Gas or H2, Methane - CH4, Propane - C3H8
- Brand Teledyne
- Part Numbers OLCT10-AP-004 OLCT 10 Fixed Gas Detectors - Catalytic - poison resistant versions - C4H10, Butane 0-100% LEL, 6513559 Flammable gas sensor type OLC 10 - Range 0-100% LEL CH4 / C4H10 / C3H8 / H2 - ATEX II 3 GD approved, OLCT10-AP-003 OLCT 10 Fixed Gas Detectors - Catalytic - poison resistant versions - H2, Hydrogen 0-100% LEL, 6513566 Flammable gas sensor type OLC 10 TWIN - Range 0-100% LEL CH4 / C4H10 / C3H8 / H2 - ATEX II 3 GD approved, OLCT10-204 OLCT 10 Fixed Gas Detectors - Electrochemical versions - CO - 0-300 ppm, OLCT10-001 OLCT 10 Fixed Gas Detectors - Catalytic versions - CH4, Methane 0-100% LEL (5% Vol), OLCT10-216 OLCT 10 Fixed Gas Detectors - Electrochemical versions - NO, 0-100 ppm, OLCT10-002 OLCT 10 Fixed Gas Detectors - Catalytic versions - CH4, Methane 0-100% LEL (4.4% Vol), OLCT10-220 OLCT 10 Fixed Gas Detectors - Electrochemical versions - NO2, 0-30 ppm, OLCT10-005 OLCT 10 Fixed Gas Detectors - Catalytic versions - C3H8, Propane 0-100% LEL, OLCT10-004 OLCT 10 Fixed Gas Detectors - Catalytic versions - C4H10, Butane 0-100% LEL, OLCT10-003 OLCT 10 Fixed Gas Detectors - Catalytic versions - H2, Hydrogen 0-100% LEL, OLCT10-AP-001 OLCT 10 Fixed Gas Detectors - Catalytic - poison resistant versions - CH4, Methane 0-100% LEL (5% Vol), OLCT10-AP-002 OLCT 10 Fixed Gas Detectors - Catalytic - poison resistant versions - CH4, Methane 0-100% LEL (4.4% Vol), OLCT10-AP-005 OLCT 10 Fixed Gas Detectors - Catalytic - poison resistant versions - C3H8, Propane 0-100% LEL
View product - BEST SELLER
SKU: OLCT100
Teledyne OLCT 100 – OLC 100 Fixed Gas Detector
- Gas Detection Class Fixed
- ATEX ATEX
- Output 4 to 20 mA
- Power Consumption Depends on Detector Type
- Brand Teledyne
- Part Numbers OLCT100-XP-200 - lameproof transmitter on board XP sensor O2 0-30% Vol. 2 year sensor (Electrochemical versions), OLCT100-XP-002 - lameproof transmitter onboard XP sensor CH4, Methane 100% LEL (4,4 % Vol.) (Catalytic versions), OLCT100-XP-203 - lameproof transmitter onboard XP sensor CO, Carbon monoxide 0-100 ppm (Catalytic versions), OLCT100-XP-003 - lameproof transmitter onboard XP sensor H2, Hydrogen 100% LEL (Catalytic versions), OLCT100-XP-006 - lameproof transmitter - with catalitic sensor on board XP sensor NH3 100% LEL (Catalytic versions)
- Gas Type FX56, Carbon Monoxide - CO, R407C, Toluene - C7H8, R134A, Ethanol, Chlorine - Cl2, R408A, Phosgene - COCl2, R32, Isopropanol, Chlorine Dioxide - ClO2, R507, R404A, 2-butanone (MEK), Formaldehyde - CH2O, R1233ZD, SF6, Xylene, Hydrogen Chloride - HCl, R407F, R11, Hydrogen Sulfide - H2S, R449A, R12, Nitrogen Dioxide - NO2, R410A, Silane - SiH4, R22, Nitric Oxide - NO, Hydrogen Cyanide - HCN, Arsine - AsH3, R23, Oxygen - O2, Methyl Chloride - CH3Cl, Ammonia - NH3, Ethylene oxide - ETO, R123, Phosphine - PH3, R1234YF, Methylene Chloride - CH2Cl2, Carbon Dioxide - CO2, Natural Gas or H2, R143A, Sulfur Dioxide - SO2, R1234ZE
View product SKU: 14082
Teledyne OLCT 60 Fixed Gas Detector
- Gas Detection Class Fixed
- ATEX ATEX
- Temperature -20 to +55 (Explosive gases)
- Output 0-23 mA (4-20 mA reserved for measurement)
- Gas Type Phosphine - PH3, SF6, R22, Chlorine - Cl2, Infrared, Sulfur Dioxide - SO2, R407F, R23, Chlorine Dioxide - ClO2, Arsine - AsH3, Phosgene - COCl2, R449A, R123, Hydrogen - H, Ethylene oxide - ETO, R410A, R143A, Hydrogen Chloride - HCl, FX56, R408A, Hydrogen Cyanide, Toluene, Ethanol, R507, Hydrogen Fluoride - HF, R1234YF, Isopropanol, R1233ZD, Hydrogen Sulfide - H2S, R1234ZE, 2-butanone (MEK), Nitric Oxide - NO, R134A, Xylene, Ammonia - NH3, Oxygen - O2, R32, R11, Carbon Dioxide - CO2, Ozone - O3, R404A, R12, Carbon Monoxide - CO, Explosive Gas (Ex)
- Brand Teledyne
View product