The Talentum IR2 Flame Detector uses advanced flame-sensing technology to reliably detect real fires while intelligently rejecting false alarm sources, delivering fast, accurate protection when it matters most.

IECExATEX

Description

Talentum 16000 Flame Detector IR2 (Ex d)

Advanced Dual-IR Sensing Technology

The Talentum 16000 IR2 (Ex d) flame detector operates by sensing the infrared (IR) radiation produced during combustion. Signals from two independent IR sensors are continuously analysed to identify the distinct flicker frequency and spectral characteristics associated with a true flame. By using this dual-sensor configuration, the detector can effectively differentiate genuine fire events from false sources of radiation, ensuring dependable and precise early fire detection.

Broad Fuel Source Detection

One of the key strengths of this advanced detection technique is its capability to detect flames generated by a broad range of fuel types. This includes hydrocarbon fires involving oil and gas, as well as certain inorganic fires. As the system does not depend on smoke particles to activate, the Talentum IR2 (Ex d) is particularly well suited to open or ventilated environments where smoke may dissipate rapidly, limiting the effectiveness of traditional smoke detectors.

Engineered for Industrial Environments

Designed with industrial reliability in mind, the detector is enclosed within a rugged housing that provides robust protection against dust and water ingress. Its efficient low-power operation, combined with flexible output options such as conventional 2-wire, 4–20 mA, and relay contacts, enables straightforward integration with existing fire alarm panels and industrial control systems, making it a versatile and dependable solution for specialist flame detection applications.

For more information, get in contact via the contact us form or call 02920 759 683.

Description

Talentum 16000 Flame Detector IR2 (Ex d)

Advanced Dual-IR Sensing Technology

The Talentum 16000 IR2 (Ex d) flame detector operates by sensing the infrared (IR) radiation produced during combustion. Signals from two independent IR sensors are continuously analysed to identify the distinct flicker frequency and spectral characteristics associated with a true flame. By using this dual-sensor configuration, the detector can effectively differentiate genuine fire events from false sources of radiation, ensuring dependable and precise early fire detection.

Broad Fuel Source Detection

One of the key strengths of this advanced detection technique is its capability to detect flames generated by a broad range of fuel types. This includes hydrocarbon fires involving oil and gas, as well as certain inorganic fires. As the system does not depend on smoke particles to activate, the Talentum IR2 (Ex d) is particularly well suited to open or ventilated environments where smoke may dissipate rapidly, limiting the effectiveness of traditional smoke detectors.

Engineered for Industrial Environments

Designed with industrial reliability in mind, the detector is enclosed within a rugged housing that provides robust protection against dust and water ingress. Its efficient low-power operation, combined with flexible output options such as conventional 2-wire, 4–20 mA, and relay contacts, enables straightforward integration with existing fire alarm panels and industrial control systems, making it a versatile and dependable solution for specialist flame detection applications.

For more information, get in contact via the contact us form or call 02920 759 683.

Technical Specification
Supply voltage: 14 to 30 Vdc
Housing Colour: Red
Dimensions: 158(h) x 149(w) x 137(d) mm (6¼"(h) x 57/8"(w) x 5⅜"(d))
Weight: 2.3 kg (5 lb)
Cable gland entries: 3 x 20 mm (3 x ¾")
Wiring: 1.0 to 4.0 mm² (12 – 18 AWG)
Power-up time: 2 seconds max
Operating temperature -10°C to +55°C (+14°F to +131°F)
Videos
FAQs
How does the Talentum IR2 prevent false alarms?

The detector uses two IR sensors that analyse the wavelength and flicker frequency of radiation from a fire. For an alarm to be triggered, the signals must match the characteristics of a real flame, allowing the detector to ignore false sources like sunlight or welding arcs.

What is the main difference between an IR2 and an IR3 flame detector?

An IR2 detector uses two infrared sensors, making it highly effective and immune to many false sources. An IR3 detector uses three sensors, providing an even higher degree of false alarm immunity, particularly from hot surfaces, making it suitable for more complex environments.

Can the Talentum IR2 detect fires with no visible flame?

Yes. The Talentum IR2 is specifically designed to detect the infrared radiation from a fire, not visible light. This makes it highly effective for detecting invisible flames.