Combustible Gas Sensor Type: Catalytic Bead (XCell combustible), Infrared (XIR Plus)
Toxic Gas & Oxygen Sensor Type: XIR PLUS: Carbon Dioxide (CO₂). XCell Toxic: Ammonia (NH₃), Carbon Monoxide (CO), Carbon Monoxide (CO) H₂-resistant, Hydrogen Sulfide (H₂S), Chlorine (Cl₂), Chlorine Dioxide (ClO2), Sulfur Dioxide (SO₂). XCell O₂: Oxygen (O₂). Electrochem: Ammonia (NH₃), Ethylene Oxide (ETO), Hydrogen (H₂), Hydrogen Chloride (HCl), Hydrogen Cyanide (HCN), Hydrogen Fluoride (HF), Nitric Oxide (NO), Nitrogen Dioxide (NO₂), Sulfur Dioxide (SO₂)
Warranty: X5000 transmitter: 2 years, XIR PLUS: 10 years source, 5 years electronics, XCell Sensors: 3 years, Electrochemical Sensors: Varies by gas
Approvals: CSA, FM*, ATEX, IECEx, INMETRO, DNV-GL Marine, CE Marking. SIL 2 suitable. Complies with C22.2 No. 152, FM 6320
Operating Temperature Range: XCell: -40°C to +60°C. Electrochem: (call to confirm). XIR PLUS:-40°C to +60°C
Relative Humidity (Non-Condensing): XCell toxics & O₂: 10-95%, XCell combustible: 0-95%, XIR PLUS: 15-95%
Input Power: 11 to 30 VDC, 3 wire
Signal Output: Dual 4-20 mA current source, HART
Relay Ratings: 5 A @ 30 VDC; 5 A @ 220 VAC (3X) SPDT - fault, warn, alarm
Relay Modes: Common, discrete, horn
EMC Directive: Complies with EN 50270, EN 61000-6-4, EN 61000-6-3
Display: Organic LED (multi-lingual) with contrast ratio of 2000:1 and view angle of 160°
HART: HART 7, HART device description language available
Faults Monitored: Low supply voltage, RAM checksum error, flash checksum error, EEPROM error, internal circuit error, relay, invalid sensor configuration, sensor faults, general system
Cable Requirements: 3-wire shielded cable for single sensor and 4-wire shielded cable for dual sensor configurations. Accommodates up to 12 AWG or 4 mm2