Gas Detection Tubes
Gas detection tubes are a highly effective solution for detecting a wide range of gases. At Rockall Safety, we stock over 120 different Drager gas detection tubes, covering toxic, flammable, and industrial gases. These tubes are designed to provide rapid measurements on the spot.
To use the gas detection tubes, break both ends of the tube using the tube opener. This ensures the reactive chemicals inside are ready to interact with the sampled air. The tube is then inserted into the Drager Accuro gas detector pump, which draws a precise, calibrated volume of air through the tube.
As the air passes through, the gas reacts with the chemicals inside the tube, causing a colour change along the printed scale. The length of this colour change corresponds to the concentration of the target gas, allowing for an accurate, immediate reading.
Industries that commonly use Drager gas detection tubes include oil and gas, chemical manufacturing, construction, environmental monitoring, and wastewater treatment. They are ideal for confined space checks, leak detection, verifying ventilation, and identifying potentially hazardous atmospheres before work begins.
While portable gas detectors offer continuous monitoring, gas detection tubes are often chosen for their ease of use and affordability.
Rockall Safety has a strong, long standing relationship with Drager, allowing us to supply the full range of gas detection tubes alongside all necessary accessories, including the pump and tube opener.
Call 02920 759 683 or Contact our sales team today to learn more about how we can help you.
Gas Detection Tubes
Gas detection tubes are a highly effective solution for detecting a wide range of gases. At Rockall Safety, we stock over 120 different Drager gas detection tubes, covering toxic, flammable, and industrial gases. These tubes are designed to provide rapid measurements on the spot.
To use the gas detection tubes, break both ends of the tube using the tube opener. This ensures the reactive chemicals inside are ready to interact with the sampled air. The tube is then inserted into the Drager Accuro gas detector pump, which draws a precise, calibrated volume of air through the tube.
As the air passes through, the gas reacts with the chemicals inside the tube, causing a colour change along the printed scale. The length of this colour change corresponds to the concentration of the target gas, allowing for an accurate, immediate reading.
Industries that commonly use Drager gas detection tubes include oil and gas, chemical manufacturing, construction, environmental monitoring, and wastewater treatment. They are ideal for confined space checks, leak detection, verifying ventilation, and identifying potentially hazardous atmospheres before work begins.
While portable gas detectors offer continuous monitoring, gas detection tubes are often chosen for their ease of use and affordability.
Rockall Safety has a strong, long standing relationship with Drager, allowing us to supply the full range of gas detection tubes alongside all necessary accessories, including the pump and tube opener.
Call 02920 759 683 or Contact our sales team today to learn more about how we can help you.
SKU: 6728181
Drager Detection Tubes (Hydrochloric Acid 50/a)
- Brand Dräger
- Product Type Gas Tubes
- Gas Type Hydrochloric Acid
- Measuring Range 50 to 5000 ppm
View productSKU: 8101681
Drager Detection Tubes (Hydrochloric Acid/Nitric Acid)
- Brand Dräger
- Product Type Gas Tubes
- Gas Type Hydrochloric Acid/Nitric Acid
- Measuring Range 0.2% to 2 vol. %
View productSKU: 8101511
Drager Detection Tubes (Hydrogen 0.2%/a)
- Brand Dräger
- Product Type Gas Tubes
- Gas Type Hydrogen - H
- Measuring Range 0.2% to 2 vol. %
View productSKU: CH30901
Drager Detection Tubes (Hydrogen 0.5%/a)
- Product Type Gas Tubes
- Gas Type Hydrogen - H
- Measuring Range 0.5% to 3 vol. %
View productSKU: 8103251
Drager Detection Tubes (Hydrogen Fluoride 0.5/a)
- Brand Dräger
- Product Type Gas Tubes
- Gas Type Hydrogen Fluoride - HF
- Measuring Range 0.5 to 90 ppm
View productSKU: CH30301
Drager Detection Tubes (Hydrogen Fluoride 1.5/b)
- Brand Dräger
- Product Type Gas Tubes
- Gas Type Hydrogen Fluoride - HF
- Measuring Range 1.5 to 60 ppm
View productSKU: 8101041
Drager Detection Tubes (Hydrogen Peroxide)
- Brand Dräger
- Product Type Gas Tubes
- Gas Type Hydrogen Peroxide - H2O2
- Measuring Range 0.1 to 3 ppm
View productSKU: 8101461
Drager Detection Tubes (Hydrogen Sulphide 0.2/a)
- Brand Dräger
- Product Type Gas Tubes
- Gas Type Hydrogen Sulfide - H2S
- Measuring Range 0.2 to 5 ppm
View productSKU: 8101831
Drager Detection Tubes (Hydrogen Sulphide 1/d)
- Brand Dräger
- Product Type Gas Tubes
- Gas Type Hydrogen Sulphide
- Measuring Range 1 to 200 ppm
View productSKU: 6728821
Drager Detection Tubes (Hydrogen Sulphide 2/a)
- Brand Dräger
- Product Type Gas Tubes
- Gas Type Hydrogen Sulphide
- Measuring Range 2 to 200 ppm
View productSKU: CH29801
Drager Detection Tubes (Hydrogen Sulphide 5/b)
- Brand Dräger
- Product Type Gas Tubes
- Gas Type Hydrogen Sulphide
- Measuring Range 5 to 60 ppm
View productSKU: 8103741
Drager Detection Tubes (i-Propanol 50/a)
- Brand Dräger
- Product Type Gas Tubes
- Gas Type i-Propanol
- Measuring Range 50 to 4000 ppm
View productSKU: 6728981
Drager Detection Tubes (Mercaptan 0.5/a)
- Brand Dräger
- Product Type Gas Tubes
- Gas Type Mercaptan
- Measuring Range 0.5 to 5 ppm
View productSKU: 8101871
Drager Detection Tubes (Mercaptan 20/a)
- Brand Dräger
- Product Type Gas Tubes
- Gas Type Mercaptan
- Measuring Range 20 to 100 ppm
View productSKU: CH23101
Drager Detection Tubes (Mercury Vapour 0.1/b)
- Brand Dräger
- Product Type Gas Tubes
- Gas Type Mercury Vapour
- Measuring Range 0.05 to 2 mg/m³
View productSKU: 8103801
Drager Detection Tubes (Methanol 20/a)
- Brand Dräger
- Product Type Gas Tubes
- Gas Type Methanol - CH3OH
- Measuring Range 20 to 250 and 200 to 2500 ppm
View product
FAQs
Dräger gas detection tubes are single use colourimetric tubes designed to measure specific gases or vapours in air. Used with a compatible hand pump such as the Dräger Accuro Pump, the tube changes colour to indicate the concentration of the target gas.
Each Dräger tube contains a chemical reagent that reacts with a specific gas. Air is drawn through the tube using a pump and if the target gas is present, the reagent changes colour. The length of the colour stain corresponds directly to the gas concentration.
Dräger tubes are available for detecting carbon monoxide, hydrogen sulphide, ammonia, benzene, chlorine and formaldehyde.
Accuracy typically falls within ±10-15%, depending on the specific tube and environmental conditions.
Unlike your typical gas detection devices, Dräger tubes do not require calibration. Each tube is factory calibrated and sealed for single use.
Most Dräger tubes have a shelf life of approximately two to three years from the date of manufacture.
Dräger gas detection tubes are strictly single use. Once air has been drawn through the tube and a reading has been taken, the chemical reaction is complete and the tube cannot be reused.