Crowcon Gasman (Rechargeable)

Call 02920 759 683 For Best Price

Description

Portable Crowcon Gasman Detector (Rechargeable)

Designed to provide safety to a user in a hazardous environment, this Portable Crowcon Gasman Detector (Rechargeable) is a reliable safety solution.

This portable gas detector offers a variety of single gas configurations, allowing the user to tailor the device to their specific requirements. Ideally suited for oil and gas industry work, this rechargeable Gasman unit provides the user with resistance against dust and water.

Included is a large LCD backlit user display that makes it easy to read the gas concentration levels and battery life, in addition to visual, audible and vibrating alarms (vivid red/ blue visual warning are displayed). Data and event logging are provided as a standard, along with a preemptive 30 day warning when your next calibration is due.

See available spare and accessories below for items that are compatible with the Crowcon Gasman series.

Compatible Gas Types

For more information, please call 02920 759 683.

Specifications

Size90 x 48 x 24 mm (3.5 x 1.9 x 0.95 ins)
WeightFlammable: 138g (4.9oz)
Toxic: 118g (4.1oz)
Oxygen: 129g (4.6oz)
Carbon monoxide: 139g (4.9oz)
Typical response times (T90)Flammable:  20s
Toxic gas:  20s
Oxygen:  10s
AlarmsAudible: 95dB; Multiple alarm options let you select distinctive tones for different alarm levels
Visible: Dual colours red/ blue flashing LEDs in a gas hazard
Internal vibrating alarm
DisplayCustom LCD with backlight, with display of gas concentration. Graphic symbols for battery (with proportional indication of remaining operation time), and display mode. Start up indication when calibration is due within 30 days, calibration overdue or service required.
Normal display: Real time gas concentration levels
Display recall: Peak readings and TWA
Data loggingFull timed datalogging with adjustable sample rate, set to 1 min. data rate as default.
900 hours storage at 1 min. interval (54,000 logs), >4800 events
BatteryRechargeable lithium battery for all gas types
Non-rechargeable lithium battery for toxics and oxygen (excluding CO2)
Operating time*Rechargeable: 12 hours minimum for flammable unit
Non-rechargeable: Up to 2 years
Sampling Optional manual aspirator
Operating temperature**-20°C to +65°C (-4°F to +149°F)
Humidity20 to 90% RH
Ingress protectionIP65
ApprovalsEurope: Toxic or O2: ATEX II 1G Ex ia IIC T4 Ga (-20°C ≤ Ta ≤ +65°C) BASEEFA04ATEX0384
Flammable: ATEX II 2G Ex ia d IIC T4 Gb (-20°C ≤ Ta ≤ +65°C) BASEEFA04ATEX0383
International: Toxic or O2: IECEx BAS05.0039
Flammable: IECEx BAS05.0038
North America: CSA Class 1 Groups A,B,C,D Division 1
StandardsEurope: EN60079-0, EN60079-11, EN60079-1
North America: CSA22.2, 152EN50270, EN50271, IEC61508, EN61779, EN45544
PC InterfaceRS232 connection from interface module in charger
RS232/USB converter available
CalibrationGasman can be routinely calibrated using Portables PC software or by using Checkbox IMH

Sensor Ranges

GasRangeStandard Alarm (UK)
Ammonia (NH3)0-1000ppm25ppm
Carbon monoxide (CO)0-1500ppm30ppm
Carbon dioxide (CO2)0.5%0.5%
Carbon monoxide (H2 filtered)0-500ppm30ppm
Chlorine (CL2)0-20ppm0.3ppm
Chlorine Dioxide (CIO₂)0-1ppm0.1ppm
Ethylene Oxide (ETO)0-10ppm3ppm
Flammable0-100% LEL20% LEL
Fluorine (F2)0-1ppm0.5ppm
Hydrogen (H2)0-2000ppmN/A
Hydrogen cyanide (HCN)0-25ppm5ppm
Hydrogen fluoride (HF)0-10 ppm1ppm
Hydrogen sulphide (H2S)0-250 ppm5ppm
Nitric oxide (NO)0-100 ppm25ppm
Nitrogen dioxide (NO2)0-20 ppm1ppm
Oxygen (O2)0-25%19/23%
Ozone (O3)0-1 ppm0.1ppm
Phosphine (PH3)0-5 ppm0.1ppm
Phosgene (COCI2)0-1 ppm0.1ppm
Sulphur dioxide (SO2)0-20 ppm1ppm